SHOTBOY™ (ELECTRIC) MODELS 12 and 16
CRYOGENIC DEFLASHING & DEBURRING SYSTEMS
FREE SAMPLE DEFLASHING

    FEATURES

  • Programmable Computer
  • 10" Color Monitor
  • Electric Power Drive
  • Tumble Action
  • High Velocity Impact
  • Media/Flash Separation
  • Bar Code Reader System
  • Removable Side Panels

 

    ADVANTAGES

  • Easy Operation
  • Increased Production Runs
  • Decreased scrap Ratio
  • Adaptable to Product Size
  • Versatile Applications
  • Compact Size
  • Clean Room Compatible
  • Easy Maintenance Access

 

     APPLICATIONS

  • Complex Rubber Medical Parts
  • Micro Electronic Parts
  • Precision Elastomeric Parts
  • R & D Part Runs
  • Miniature Aerospace Products

Patents Pending



Model 12 Dimensions
Width 44.25"
Height 67.75"
Depth (Doors Closed) 42.75"
Depth (Doors Open) 67.50"

Model 16 Dimensions
Width 47.87"
Height 70.75"
Depth (Doors Closed) 43.75"
Depth (Doors Open) 73.00"


TECHNICAL & OPERATINGSPECIFICATIONS
Power Requirements:
220 VAC, 3 Phase 20 AMP, 50/60 HZ, grounded.
Media Throwing Wheel:
4" Diameter with speed range to 20,000 RPM for high velocity impact. Motor is an Electric Brushless/DC, with Direct Drive hook-up and matching Controller Board.
Parts Basket:
(Stainless Steel)
SB-12 = 12" dia. x 12" deep
SB-16 = 16" dia. x 16" deep
Perforation is 0.250 Ø standard
Refrigerant:
Liquid Nitrogen at -320º F. at 50 PSIG maximum.
Media/Flash Separator:
Housed in the lower compartment for separating media, flash and fine particles.
Processor Controls:
Programmable micro-processing computer with 9999 processing programs. All applicable functions displayed on the color monitor with bar code reader system.
Media Flow System:
Gaseous Nitrogen or Clean/Dry Shop Air (30/35 PSIG)
Media Type:
System can operate utilizing any plastic blast media.
Insulation:
2" Thick rigid, high density polyurethane foam for cold containment around inner blast chamber.
Gaseous Nitrogen:
Using an ambient vaporizer (500 scfh) to create GN
2 for the media assist system.
   